Safety, walking ability, and satisfaction outcomes of the NEURO TRONIC stance-control knee-ankle-foot orthosis (SCKAFO): A comparative evaluation to the E-MAG active SCKAFO

NEURO TRONIC 站立控制型膝踝足矫形器 (SCKAFO) 的安全性、行走能力和满意度结果:与 E-MAG 主动式 SCKAFO 的比较评估

阅读:2

Abstract

BACKGROUND: Stance control knee-ankle-foot orthoses (SCKAFOs) ensure knee stability by locking during stance while allowing knee flexion during swing. Differences in function of the knee joints and building principles between devices may affect their effectiveness. OBJECTIVE: To investigate the preliminary effectiveness of a NEURO TRONIC on safety outcomes, net energy cost (EC), and user experiences in individuals already using an E-MAG Active SCKAFO. STUDY DESIGN: Prospective uncontrolled intervention study. METHODS: A convenience sample of 10 subjects with flaccid lower extremity muscle weakness, including the quadriceps, due to neuromuscular disorders already using an E-MAG Active SCKAFO were provided with a newly fabricated NEURO TRONIC SCKAFO. Outcomes included knee joint locking failures and unlocking failures (ULFs) (i.e., percentage of steps the knee joint failed to lock/unlock) when walking under challenging conditions on an instrumented treadmill while wearing a safety harness; net EC (J/kg per meter) assessed with a 6-min walk test at comfortable speed; 3D gait kinematics and kinetics; and patient-reported outcomes. RESULTS: No differences between devices were found for knee joint locking failures (both devices 0%) and ULFs (9.9% for the NEURO TRONIC vs. 13.9% for the E-MAG Active SCKAFO). The mean (standard deviation) net EC with the NEURO TRONIC SCKAFO was 8.2% (from 3.68 [0.81] to 3.38 [0.75] J/kg per meter, p = 0.123) lower, although not significantly, compared with that with the E-MAG Active SCKAFO. Significant improvements with the NEURO TRONIC SCKAFO were found for ankle power ( p = 0.003), perceived walking effort ( p = 0.014), and reported falls ( p = 0.034). CONCLUSION: Both the NEURO TRONIC SCKAFO and the E-MAG Active SCKAFO were safe in terms of knee joint locking, while ULFs were frequent with both devices. The net EC with the NEURO TRONIC SCKAFO decreased, although not significantly, by 8.2%, likely due to insufficient power. Perceived walking effort was in favor of the NEURO TRONIC SCKAFO.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。