Evaluation of an implemented new insulin chart to improve quality and safety of diabetes care in a large university hospital: a follow-up study

评估一项在大型大学医院实施的新型胰岛素治疗方案对提高糖尿病护理质量和安全性的效果:一项后续研究

阅读:1

Abstract

OBJECTIVES: To evaluate structure, documentation, treatment quality of a new implemented standardised insulin chart in adult medical inpatient wards at a university hospital. DESIGN: A before-after study (3 to 5 months after implementation) was used to compare the quality of old versus new insulin charts. SETTING: University Hospital Graz, Austria. PARTICIPANTS: Healthcare professionals (n=237) were questioned regarding structure quality of blank insulin charts. INTERVENTIONS: A new standardised insulin chart was implemented and healthcare professionals were trained regarding features of this chart. Data from insulinised inpatients were evaluated regarding documentation and treatment quality of filled-in insulin charts (n=108 old insulin charts vs n=100 new insulin charts). MAIN OUTCOMES AND MEASURES: The primary endpoint was documentation error for insulin administration. RESULTS: Healthcare professionals reported an improved structure quality of the new insulin chart with a Likert type response scale increase in all nine items. Documentation errors for insulin administration (primary endpoint) occurred more often on old than new insulin charts (77% vs 5%, p<0.001). Documentation errors for insulin prescription were more frequent on old insulin charts (100% vs 42%) whereas documentation errors for insulin management rarely occurred in any group (10% vs 8%). Patients of both chart evaluation groups (age: 71±11 vs 71±12 years, 47% vs 42% women, 75% vs 87% type 2 diabetes for old vs new charts, respectively) had a mean of 4±2 good diabetes days. Overall, 26 vs 18 hypoglycaemic episodes (blood glucose (BG) <4.0 mmol/L (72 mg/dL), p=0.28), including 7 vs 2 severe hypoglycaemic episodes (BG <3.0 mmol/L (54 mg/dL), p=0.17) were documented on old versus new insulin charts. CONCLUSIONS: The implementation of a structured documentation form together with training measures for healthcare professionals led to less documentation errors and safe management of glycaemic control in hospitalised patients in a short time follow-up. A rollout at further medical wards is recommended, and sustainability in the long-term has to be demonstrated.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。