Retention, Bacterial Adhesion, and Biofilm Formation between Anionic and Zwitterionic Bandage Contact Lenses in Healthy Dogs: A Pilot Study

健康犬佩戴阴离子和两性离子绷带式隐形眼镜时的滞留、细菌粘附和生物膜形成:一项初步研究

阅读:1

Abstract

This study aimed to compare the in vitro and in vivo retention, bacterial adhesion, and biofilm formation between anionic and zwitterionic bandage contact lenses (BCLs) in healthy canines. BCL retention and tolerance were evaluated in 10 healthy canines via a single-masked, crossover study for 7 days. To compare in vitro bacterial adhesion and biofilm formation, four Staphylococcus strains were incubated with the BCLs at 37 °C for 2 or 24 h, and the bacterial colony forming units (CFUs) adhering to the BCLs were counted. Next, to compare in vivo bacterial adhesion, the CFUs of bacteria adhering to the BCLs worn by canines for 24 h were counted. Anionic lenses significantly retained and reduced in vitro bacterial adhesion than in the zwitterionic lenses. However, the amount of in vitro biofilm formation was more likely to be higher on anionic lenses than on zwitterionic lenses. In vivo bacterial adhesion was not significantly different between the two types of BCLs. Nevertheless, both BCLs were well-tolerated by the canines; thus, their short-term use in dogs can be recommended as safe.