The Effect of Lung Volume on the Size and Volume of Pulmonary Subsolid Nodules on CT: Intraindividual Comparison between Total Lung Capacity and Tidal Volume

肺容量对CT上肺亚实性结节大小和体积的影响:肺总量与潮气量的个体间比较

阅读:1

Abstract

PURPOSE: To examine the effect of lung volume on the size and volume of pulmonary subsolid nodules (SSNs) measured on CT. MATERIALS AND METHODS: A total of 42 SSNs from 31 patients were included. CT examination was first performed at total lung capacity (TLC), and a section containing the nodule was additionally scanned at tidal volume (TV). The diameter and volume of each SSN, as well as the cross-sectional lung area containing the nodule, were measured. The significance of the changes in measurements between TLC and TV within the same individuals was evaluated. RESULTS: The lung area and the diameter and volume of SSNs decreased significantly at TV by 12.7 cm(2), 0.5 mm, and 46.4 mm(3) on average, respectively (p < 0.001), compared to those at TLC. Changes in lung area between TV and TLC were positively correlated with the change in SSN diameter (p = 0.027) and volume (p = 0.014). However, after correction (by considering the change in lung area), the changes in SSN diameter (p = 0.124) and volume (p = 0.062) were not significantly different. CONCLUSION: SSN size and volume can be significantly affected by lung volume during CT scans of the same individuals.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。