The diagnostic value and efficacy evaluation of lung ultrasound score in neonatal respiratory distress syndrome: a prospective observational study

肺部超声评分在新生儿呼吸窘迫综合征诊断中的价值和疗效评价:一项前瞻性观察研究

阅读:1

Abstract

OBJECTIVE: To evaluate the diagnostic efficacy and determine the optimal cut-off values of lung ultrasound score for diagnosing neonatal respiratory distress syndrome and its accuracy in assessing the efficacy of neonatal respiratory distress syndrome. METHOD: This prospective study included 100 neonates with suspected neonatal respiratory distress syndrome. Each patient underwent both the 14-zone and 12-zone lung ultrasound methods, as well as a chest x-ray, performed after birth and before initiating drug treatment. Surfactant replacement therapy was administered to patients who were diagnosed with neonatal respiratory distress syndrome and met the criteria for medication. Lung ultrasound was conducted and recorded at the 24th hour, the 48th hour, the 72nd hour, and the 7th day after drug administration. ROC curve analysis, Kappa statistics, and ANOVA were utilized to identify the optimal cut-off values for the lung ultrasound scores in diagnosing neonatal respiratory distress syndrome. RESULTS: 89 neonates were diagnosed with respiratory distress syndrome, of whom 64 received surfactant replacement therapy. The mean scores of 12-zone lung ultrasound score, 14-zone lung ultrasound score, and chest x-ray score are 18.22 ± 7.15, 38.92 ± 9.69, and 2.15 ± 0.97, respectively. The diagnostic AUC for the 12-zone lung ultrasound score is 0.84 (95% CI: 0.73-0.95), with an optimal cut-off value of 13.5 for diseased vs. not diseased, while the AUC for the 14-zone lung ultrasound score is 0.88 (95% CI: 0.76-0.99), with an optimal cut-off value of 34 for diseased vs. not diseased. There is significant concordance between the neonatal lung ultrasonography scores and the chest x-ray score for diagnosis respiratory distress syndrome (P < 0.01). The optimal cut-off values for the grading diagnosis of neonatal respiratory distress syndrome using the 14-zone lung ultrasound score are identified as 36.5, 40.5, and 44.5. The 12-zone lung ultrasound score does not have a significant difference between the 12th hour after receiving surfactant replacement therapy and the 48th hour after treatment (P = 0.08). All other comparisons demonstrated significant differences. CONCLUSION: The 14-zone lung ultrasound score demonstrates higher diagnostic efficacy in diagnosing neonatal respiratory distress syndrome and can accurately evaluate the early efficacy of surfactant replacement therapy in neonates.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。