Evaluating MIR and NIR Spectroscopy Coupled with Multivariate Analysis for Detection and Quantification of Additives in Tobacco Products

评估中红外和近红外光谱结合多元分析在烟草制品添加剂检测和定量中的应用

阅读:1

Abstract

The detection and quantification of additives in tobacco products are critical for ensuring consumer safety and compliance with regulatory standards. Traditional analytical techniques, like gas chromatography-mass spectrometry (GC-MS), liquid chromatography-mass spectrometry (LC-MS), and others, although effective, suffer from drawbacks, including complex sample preparation, high costs, lengthy analysis times, and the requirement for skilled operators. This study addresses these challenges by evaluating the efficacy of mid-infrared (MIR) spectroscopy and near-IR (NIR) spectroscopy, coupled with multivariate analysis, as potential solutions for the detection and quantification of additives in tobacco products. So, a representative set of tobacco products was selected and spiked with the targeted additives, namely caffeine, menthol, glycerol, and cocoa. Multivariate analysis of MIR and NIR spectra consisted of principal component analysis (PCA), hierarchical clustering analysis (HCA), partial least squares-discriminant analysis (PLS-DA) and soft independent modeling of class analogy (SIMCA) to classify samples based on targeted additives. Based on the unsupervised techniques (PCA and HCA), a distinction could be made between spiked and non-spiked samples for all four targeted additives based on both MIR and NIR spectral data. During supervised analysis, SIMCA achieved 87-100% classification accuracy for the different additives and for both spectroscopic techniques. PLS-DA models showed classification rates of 80% to 100%, also demonstrating robust performance. Regression studies, using PLS, showed that it is possible to effectively estimate the concentration levels of the targeted molecules. The results also highlight the necessity of optimizing data pretreatment for accurate quantification of the target additives. Overall, NIR spectroscopy combined with SIMCA provided the most accurate and robust classification models for all target molecules, indicating that it is the most effective single technique for this type of analysis. MIR, on the other hand, showed the overall best performance for quantitative estimation.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。