Lung SBRT: Dose gradient optimization based on target size

肺部立体定向放射治疗:基于靶区大小的剂量梯度优化

阅读:1

Abstract

This study investigated optimization settings that steepen the dose gradient as a function of target size for lung stereotactic body radiation therapy (SBRT). Sixty-eight lung SBRT patients with planning target volumes (PTVs) ranging from 2-203 cc were categorized into small (<20 cc), medium (20-50 cc), and large (>50 cc) groups. VMAT plans were generated using the normal tissue objective (NTO) to penalize the dose gradient at progressively steeper NTO fall-off values (0.1, 0.2, 0.3, 0.4, 0.5 mm(-1)). Dose was calculated using the AcurosXB algorithm and was normalized so the prescription dose covered 95% of the PTV. Mann-Whitney, Kruskal-Wallis and ANOVA tests were used to assess for statistical differences in the Conformity Index at the 50% isodose level (CI50%), global maximum dose (D(max)), and monitor units (MU) across the various NTO settings. All plans adhered to institutional criteria and met the guidelines of the Radiation Therapy Oncology Group 0813. Steeper NTO fall-off values significantly increased D(max) and MUs across all groups (p < 0.05). CI50% significantly differed with fall-off values in small (0.3 mm(-1)) and medium (0.2 mm(-1)) targets, indicating steeper NTO fall-off values improve CI50% for small and medium targets (p < 0.05). Large targets showed no significant CI50% difference across these fall-off values. As target size increases, the importance of fall-off values in achieving an acceptable CI50% diminishes. Smaller targets benefit from steeper fall-off values despite increased D(max) and MUs. Consideration of fall-off value relative to target size is crucial to limit dose spillage outside the target.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。