A lung SBRT treatment planning technique to focus high dose on gross disease

一种肺部立体定向放射治疗(SBRT)治疗计划技术,旨在将高剂量聚焦于大面积病灶。

阅读:1

Abstract

This study investigated a straightforward treatment planning technique for definitive stereotactic body radiation therapy (SBRT) for patients with early-stage lung cancer aimed at increasing dose to gross disease by strategically penalizing the normal tissue objective (NTO) in the Eclipse(TM) treatment planning system. Twenty-five SBRT cases were replanned to 50 Gy in 5 fractions using static and dynamic NTO methods (50 plans total). The NTO had a start dose of 100% at the target border, end dose of 20%, fall-off rate of 0.4/mm, and a priority of 150. For the static NTO plans, a lower planning target volume (PTV) objective was placed at 52 Gy with a priority of 100. Maximum dose was not penalized. Optimization was performed without user interaction. In contrast, the planner incrementally increased the priority of the NTO on the dynamic NTO plans until 95% of the target volume was covered by the prescription dose. Further, the dynamic NTO plans used both PTV lower and upper objectives at 63-64 Gy with priorities of 50. Maximum dose was penalized to ensure that the hot spot was within ± 2% of the static NTO global maximum dose. Following optimization, all plans were normalized so that the prescription dose covered 95% of the PTV. Plans were scored based on RTOG 0813 criteria, and dose to the internal target volume (ITV) and PTV was evaluated. The Wilcoxon signed-rank test (threshold = 0.05) was used to evaluate differences between the static and dynamic NTO plans. All plans met RTOG 0813 planning guidelines. In comparison to the static NTO plans, the dynamic NTO plans exhibited statistically significant increases in PTV mean dose, ITV mean dose, and PTV-ITV mean dose. Notably, the dynamic NTO plans more effectively concentrated the high dose on gross disease at the center of the PTV. As compared to the static NTO plans, the mean dose was 4.6 Gy higher in the ITV while only 1.3 Gy higher in the PTV-ITV rind of the dynamic NTO plans. Global maximum doses were similar. There were some small yet statistically significant differences in dose conformity between plan types. Furthermore, the dynamic NTO plans demonstrated a significant reduction in total monitor units (MU). This study demonstrated an efficient optimization strategy for lung SBRT plans that concentrates the highest dose in the gross disease, which may improve local control.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。