Application of In vitro transcytosis models to brain targeted biologics

将体外胞吞作用模型应用于靶向脑组织的生物制剂

阅读:1
作者:Kangwen Deng ,Yifeng Lu ,Sjoerd J Finnema ,Kostika Vangjeli ,Junwei Huang ,Lili Huang ,Andrew Goodearl

Abstract

The blood brain barrier (BBB) efficiently limits the penetration of biologics drugs from blood to brain. Establishment of an in vitro BBB model can facilitate screening of central nervous system (CNS) drug candidates and accelerate CNS drug development. Despite many established in vitro models, their application to biologics drug selection has been limited. Here, we report the evaluation of in vitro transcytosis of anti-human transferrin receptor (TfR) antibodies across human, cynomolgus and mouse species. We first evaluated human models including human cerebral microvascular endothelial cell line hCMEC/D3 and human colon epithelial cell line Caco-2 models. hCMEC/D3 model displayed low trans-epithelial electrical resistance (TEER), strong paracellular transport, and similar transcytosis of anti-TfR and control antibodies. In contrast, the Caco-2 model displayed high TEER value and low paracellular transport. Anti-hTfR antibodies demonstrated up to 70-fold better transcytosis compared to control IgG. Transcytosis of anti-hTfR.B1 antibody in Caco-2 model was dose-dependent and saturated at 3 μg/mL. Enhanced transcytosis of anti-hTfR.B1 was also observed in a monkey brain endothelial cell based (MBT) model. Importantly, anti-hTfR.B1 showed relatively high brain radioactivity concentration in a non-human primate positron emission tomography study indicating that the in vitro transcytosis from both Caco-2 and MBT models aligns with in vivo brain exposure. Typically, brain exposure of CNS targeted biologics is evaluated in mice. However, antibodies, such as the anti-human TfR antibodies, do not cross-react with the mouse target. Therefore, validation of a mouse in vitro transcytosis model is needed to better understand the in vitro in vivo correlation. Here, we performed transcytosis of anti-mouse TfR antibodies in mouse brain endothelial cell-based models, bEnd3 and the murine intestinal epithelial cell line mIEC. There is a good correlation between in vitro transcytosis of anti-mTfR antibodies and bispecifics in mIEC model and their mouse brain uptake. These data strengthen our confidence in the predictive power of the in vitro transcytosis models. Both mouse and human in vitro models will serve as important screening assays for brain targeted biologics selection in CNS drug development.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。