Nasopharyngeal cancer adaptive radiotherapy with CBCT-derived synthetic CT: deep learning-based auto-segmentation precision and dose calculation consistency on a C-Arm linac

基于CBCT衍生合成CT的鼻咽癌自适应放射治疗:C臂直线加速器上基于深度学习的自动分割精度和剂量计算一致性

阅读:1

Abstract

BACKGROUND: To evaluate the precision of automated segmentation facilitated by deep learning (DL) and dose calculation in adaptive radiotherapy (ART) for nasopharyngeal cancer (NPC), leveraging synthetic CT (sCT) images derived from cone-beam CT (CBCT) scans on a conventional C-arm linac. MATERIALS AND METHODS: Sixteen NPC patients undergoing a two-phase offline ART were analyzed retrospectively. The initial (pCT(1)) and adaptive (pCT(2)) CT scans served as gold standard alongside weekly acquired CBCT scans. Patient data, including manually delineated contours and dose information, were imported into ArcherQA. Using a cycle-consistent generative adversarial network (cycle-GAN) trained on an independent dataset, sCT images (sCT(1), sCT(4), sCT(4)(*)) were generated from weekly CBCT scans (CBCT(1), CBCT(4), CBCT(4)) paired with corresponding planning CTs (pCT(1), pCT(1), pCT(2)). Auto-segmentation was performed on sCTs, followed by GPU-accelerated Monte Carlo dose recalculation. Auto-segmentation accuracy was assessed via Dice similarity coefficient (DSC) and 95th percentile Hausdorff distance (HD(95)). Dose calculation fidelity on sCTs was evaluated using dose-volume parameters. Dosimetric consistency between recalculated sCT and pCT plans was analyzed via Spearman's correlation, while volumetric changes were concurrently evaluated to quantify anatomical variations. RESULTS: Most anatomical structures demonstrated high pCT-sCT agreement, with mean values of DSC > 0.85 and HD(95) < 5.10 mm. Notable exceptions included the primary Gross Tumor Volume (GTVp) in the pCT(2)-sCT(4) comparison (DSC: 0.75, HD(95): 6.03 mm), involved lymph node (GTVn) showing lower agreement (DSC: 0.43, HD(95): 16.42 mm), and submandibular glands with moderate agreement (DSC: 0.64-0.73, HD(95): 4.45-5.66 mm). Dosimetric analysis revealed the largest mean differences in GTVn D(99): -1.44 Gy (95% CI: [-3.01, 0.13] Gy) and right parotid mean dose: -1.94 Gy (95% CI: [-3.33, -0.55] Gy, p < 0.05). Anatomical variations, quantified via sCTs measurements, correlated significantly with offline adaptive plan adjustments in ART. This correlation was strong for parotid glands (ρ > 0.72, p < 0.001), a result that aligned with sCT-derived dose discrepancy analysis (ρ > 0.57, p < 0.05). CONCLUSION: The proposed method exhibited minor variations in volumetric and dosimetric parameters compared to prior treatment data, suggesting potential efficiency improvements for ART in NPC through reduced human dependency.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。