Reliability of mechanical ventilation during continuous chest compressions: a crossover study of transport ventilators in a human cadaver model of CPR

持续胸外按压期间机械通气的可靠性:一项在人体尸体心肺复苏模型中对转运呼吸机进行的交叉研究

阅读:1

Abstract

BACKGROUND: Previous studies have stated that hyperventilation often occurs in cardiopulmonary resuscitation (CPR) mainly due to excessive ventilation frequencies, especially when a manual valve bag is used. Transport ventilators may provide mandatory ventilation with predetermined tidal volumes and without the risk of hyperventilation. Nonetheless, interactions between chest compressions and ventilations are likely to occur. We investigated whether transport ventilators can provide adequate alveolar ventilation during continuous chest compression in adult CPR. METHODS: A three-period crossover study with three common transport ventilators in a cadaver model of CPR was carried out. The three ventilators 'MEDUMAT Standard²', 'Oxylog 3000 plus', and 'Monnal T60' represent three different interventions, providing volume-controlled continuous mandatory ventilation (VC-CMV) via an endotracheal tube with a tidal volume of 6 mL/kg predicted body weight. Proximal airflow was measured, and the net tidal volume was derived for each respiratory cycle. The deviation from the predetermined tidal volume was calculated and analysed. Several mixed linear models were calculated with the cadaver as a random factor and ventilator, height, sex, crossover period and incremental number of each ventilation within the period as covariates to evaluate differences between ventilators. RESULTS: Overall median deviation of net tidal volume from predetermined tidal volume was - 21.2 % (IQR: 19.6, range: [- 87.9 %; 25.8 %]) corresponding to a tidal volume of 4.75 mL/kg predicted body weight (IQR: 1.2, range: [0.7; 7.6]). In a mixed linear model, the ventilator model, the crossover period, and the cadaver's height were significant factors for decreased tidal volume. The estimated effects of tidal volume deviation for each ventilator were - 14.5 % [95 %-CI: -22.5; -6.5] (p = 0.0004) for 'Monnal T60', - 30.6 % [95 %-CI: -38.6; -22.6] (p < 0.0001) for 'Oxylog 3000 plus' and - 31.0 % [95 %-CI: -38.9; -23.0] (p < 0.0001) for 'MEDUMAT Standard²'. CONCLUSIONS: All investigated transport ventilators were able to provide alveolar ventilation even though chest compressions considerably decreased tidal volumes. Our results support the concept of using ventilators to avoid excessive ventilatory rates in CPR. This experimental study suggests that healthcare professionals should carefully monitor actual tidal volumes to recognise the occurrence of hypoventilation during continuous chest compressions.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。