Evaluation of applicability of the Sartorius Airport MD8 sampler for detection of Bacillus endospores in indoor air

评估 Sartorius Airport MD8 采样器在室内空气中检测芽孢杆菌内生孢子的适用性

阅读:1

Abstract

This study was designed to evaluate the measuring range and lowest limit of detection of Bacillus endospores in the ambient room air when the Sartorius MD8 sampler, and two different culture methods for bacterial enumeration were used. Different concentrations of bioaerosol were generated inside the test chamber filled with either the high-efficiency particulate air (HEPA)-filtered air or with the ambient room air. The detection of endospores in the HEPA-filtered air was achievable: (1) when they were aerosolized at a concentration above 7.56 × 10(3) CFU/m(3) and analyzed with spread plate method, and (2) when they were aerosolized at a concentration above 4.00 × 10(2) CFU/m(3) and analyzed with pour plate method. The detection of endospores in the ambient room air was possible: (1) when they were aerosolized at a concentration above 9.1 × 10(3) CFU/m(3) and analyzed with spread plate method, and (2) when they were aerosolized at a concentration above 5.6 × 10(2) CFU/m(3) and analyzed with pour plate method. The microorganisms present in the ambient room air interfere with precise quantification of Bacillus endospores when their concentration is relatively low. The results of this study may be helpful in critical assessment of the results obtained from monitoring the air for bacterial endospores.