Sensitivity of modeled residential fine particulate matter exposure to select building and source characteristics: A case study using public data in Boston, MA

模拟住宅细颗粒物暴露对特定建筑物和污染源特征的敏感性:以马萨诸塞州波士顿的公共数据为例

阅读:1

Abstract

Many techniques for estimating exposure to airborne contaminants do not account for building characteristics that can magnify contaminant contributions from indoor and outdoor sources. Building characteristics that influence exposure can be challenging to obtain at scale, but some may be incorporated into exposure assessments using public datasets. We present a methodology for using public datasets to generate housing models for a test cohort, and examined sensitivity of predicted fine particulate matter (PM(2.5)) exposures to selected building and source characteristics. We used addresses of a cohort of children with asthma and public tax assessor's data to guide selection of floorplans of US residences from a public database. This in turn guided generation of coupled multi-zone models (CONTAM and EnergyPlus) that estimated indoor PM(2.5) exposure profiles. To examine sensitivity to model parameters, we varied building floors and floorplan, heating, ventilating and air-conditioning (HVAC) type, room or floor-level model resolution, and indoor source strength and schedule (for hypothesized gas stove cooking and tobacco smoking). Occupant time-activity and ambient pollutant levels were held constant. Our address matching methodology identified two multi-family house templates and one single-family house template that had similar characteristics to 60 % of test addresses. Exposure to infiltrated ambient PM(2.5) was similar across selected building characteristics, HVAC types, and model resolutions (holding all else equal). By comparison, exposures to indoor-sourced PM(2.5) were higher in the two multi-family residences than the single family residence (e.g., for cooking PM(2.5) exposure, by 26 % and 47 % respectively) and were sensitive to HVAC type and model resolution. We derived the influence of building characteristics and HVAC type on PM(2.5) exposure indoors using public data sources and coupled multi-zone models. With the important inclusion of individualized resident behavior data, similar housing modeling can be used to incorporate exposure variability in health studies of the indoor residential environment.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。