Histopathological analysis of residual lens cells in capsular opacities after cataract surgery using objective software

使用客观软件对白内障手术后囊膜混浊中残留晶状体细胞进行组织病理学分析

阅读:11
作者:Christina Mastromonaco, Matthew Balazsi, Jacqueline Coblentz, Ana Beatriz Toledo Dias, Pablo Zoroquiain, Miguel N Burnier Jr

Conclusion

This study demonstrated that SMA and FN expression is different according to IOL design and patient factors, thus indicating that LEC changes depend on lens biocompatibility. Therefore, by analyzing the histopathological composition of PCO by using LECs, further insight into the characteristics of IOLs that are important for biocompatibility can be ascertained.

Methods

In total, 190 CBs with IOLs were removed from donor eyes. Digital images were obtained, and PCO was graded using published software (ADOS, Medical Parachute). Automated immunohistochemistry was performed using anti-SMA to detect EMT and anti-FN to document ECM remodeling. Slides were digitized and analyzed using the Positive Pixel Count v9 algorithm. Linear regression and Poisson regression were performed (P < 0.05).

Purpose

Remnant lens epithelial cells (LECs) within the capsular bag (CB) undergo epithelial-to-mesenchymal transition (EMT) and acquire a myofibroblast phenotype, depositing extracellular matrix (ECM) components, leading to posterior capsular opacification (PCO). This study histopathologically analyzes the LEC-to-myofibroblast transition and de novo ECM component deposition (i.e., smooth muscle actin (SMA) and fibronectin (FN) expression) and determines the intraocular lens (IOL) and patient factors associated with these changes.

Results

SMA positive expression decreased as the time of IOL implantation increased (P < 0.0001). Positivity of SMA and FN demonstrated a positive correlation (P = 0.0002). Controlling for confounding factors in Poisson regression, hydrophobic and hydrophilic materials showed higher FN and SMA expression when compared to silicone material lenses (FN; P = 0.018; P < 0.0001, SMA; P = 0.001; P = 0.003, respectively). The square optic design had 29% higher SMA positivity compared to the opti-edge design (P = 0.042). One-piece haptic lenses had higher SMA expression compared to three-piece haptic (P = 0.042). A higher risk of expression of SMA and FN was seen in patients with a history of smoking, hypertension, and glaucoma (P < 0.05).