National diagnostic reference levels for digital diagnostic and screening mammography in Uganda

乌干达数字诊断和筛查乳腺X线摄影国家诊断参考水平

阅读:1

Abstract

INTRODUCTION: Screening and diagnostic mammography are associated with some risk of radiation-induced breast cancer. This study was conducted to establish the National Diagnostic Reference Levels (NDRLs) for digital diagnostic and screening mammography in Uganda to achieve breast radiation dose optimization. METHODS: A cross-sectional study was conducted among female participants recruited by consecutive sampling from three selected hospitals with digital mammography in Uganda. The study variables extracted from the mammography machines were exposure factors, compressed breast thickness (CBT), and Average Glandular Dose (AGD) of two standard mammogram views. The stratified National DRL was derived by calculating the 75th percentile of the AGD across all the samples at various CBT ranges for both screening and diagnostic mammography in craniocaudal (CC) and mediolateral oblique (MLO) views. RESULTS: We included 300 participants with mean ages of 50.28±9.32 and 47.45±13.45 years for the screening and diagnostic mammography, respectively. There were statistically significant positive correlations between AGD and exposure factors (mAs, kVp) (all p-values<0.0001). For screening mammography, mAs demonstrated a strong positive correlation (r = 0.8369 in CC, 0.8133 in MLO), whereas kVp showed a positive correlation with relatively lower coefficients (r = 0.3700 in CC, 0.3080 in MLO). For diagnostic mammography, mAs exhibited an even stronger positive correlation (r = 0.8987 in CC, 0.8762 in MLO), and kVp maintained a positive correlation with somewhat lower coefficients (r = 0.4954 in CC, 0.3597 in MLO). In screening mammography, for CBT within the range of (7-39) mm, the NDRLs were (1.5mGy, 1.66mGy) in CC) and MLO views. For CBT in the range of (40-59) mm, the NDRLs were (1.78mGy, 1.87mGy), and for CBT in the range of (60-99) mm, the NDRLs were (2.18mGy, 2.22mGy). For diagnostic mammography, the NDRLs were established as (1.7mGy, 1.91mGy), (2.00mGy, 2.09mGy), and (2.63mGy, 2.81mGy) for CBT ranges of (7-39) mm, (40-59) mm, and (60-99) mm, respectively. CONCLUSION: The NDRLs for digital screening and diagnostic mammography in Uganda have been proposed for the first time. The NDRL values in mammography should be specific to CBT ranges and mammographic views for both diagnostic and screening mammography.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。