Contrast-Enhanced Computed Tomography (CT) With Concordant Sonography as Sufficient Early Detection Tools for Recurrent and Persistent Cervical Metastases After (Chemo)radiotherapy (CRT)

对比增强计算机断层扫描(CT)联合超声检查可作为(化疗)放疗(CRT)后复发性和持续性宫颈转移瘤的早期检测有效手段

阅读:1

Abstract

BACKGROUND: Most challenging treatment needs are in recurrent or persisting head and neck squamous cell carcinoma (HNSCC) patients after (((chemo-)radiotherapy) (C)RT). MATERIALS AND METHODS: This 10-year retrospective study included 100 patients, who initially received (C)RT followed by neck dissection (ND). The results of computed tomography (CT) and sonography were evaluated for residual/recurrent cervical lymph nodes and compared to the histopathology. On this basis we calculate the sensitivity, specificity, negative predictive value (NPV) and positive predictive value (PPV). RESULTS: A total of 144 ND specimens were analyzed. The combination of CT and sonography (n = 103) reached values 97% sensitivity, 71% specificity, 98% NPV, 66% PPV, and 81% overall accuracy. For patients who received as primary treatment CRT the values for the combined imaging were: 100.0%, 73.5%, 100.0%, 66.7% and 82.7% respectively. CONCLUSION: Our study demonstrates that the combined use of CT and sonography reliably detects lymph node metastases, particularly in patients previously treated with CRT, even after a long time after treatment.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。