Abstract
Based on the engineering background of the Huaibei Coal Preparation Plant in Anhui Province, China, this study aims to effectively mitigate dust pollution during the blanking process at coal transfer points. Given the limitations of conventional dust control measures, a numerical simulation was conducted using the Euler model and discrete element method (DEM) for simulating particulate matter. The simulation incorporated the two-way coupling effect between gas-solid two-phase flow and the collision-adhesion dynamics among particles. We examined the migration behavior of dust within an unpowered dust removal system under various technical parameters. Results indicate that installing a return pipe significantly reduces dust overflow caused by impact airflow during blanking. Specifically, when the return pipe diameter is 500 mm, and the horizontal distance between the drainage port of the return pipe and the bottom of the blanking pipe is 2000 mm, the dust removal efficiency reaches its optimal level. Field tests confirmed that after implementing the improved dust removal system, the ambient air dust concentration decreased to less than 2 mg/m³, representing a reduction of approximately 92.02% compared to pre-transformation levels. This approach overcomes the limitations of traditional dust prevention technologies, inhibits dust generation at its source within the coal conveying system, effectively reduces working space dust concentrations, and ensures occupational health and safety for workers.