Microbiological indoor air quality and associated factors in private clinics of Harar Town, Eastern Ethiopia

埃塞俄比亚东部哈拉尔镇私人诊所的室内空气微生物质量及其相关因素

阅读:1

Abstract

BACKGROUND: Indoor air pollution, including airborne microorganisms, can cause allergies, respiratory diseases, and immune-toxic diseases. Sneezing generates millions of airborne microbial infections, and ventilation sources alter microbial communities. Few studies exist in developing countries, including Ethiopia, and Harar Town. The aim is to assess microbial indoor air quality and associated factors among private clinics, Harar town, Eastern Ethiopia. METHODOLOGY: A cross-sectional study was conducted on 260 private clinic rooms in Harar town, using a systematic random sampling method and passive air sampling. Data was collected using the settle plate method and an observation checklist. Bivariate and multivariate analysis was performed using binary logistic regression, with a P-value of <0.05 considered statistically significant. RESULT: The minimum and maximum bacterial loads were 3933 CFU/m3 and 92 CFU/m3 respectively. Based on the pollution degree of the European Commission, the Mean bacterial load (904 CFU/m3) was at higher bacterial load. The highest, lowest, and mean fungal loads were 1967 CFU/m3, 9 CFU/m3 and 401 CFU/m3 respectively. Temperature of <25 °C (AOR = 1.58, p = 0.04, and 95% CI = 1.05, 1.91), >28 °C (AOR = 1.23, P = 0.03, and 95% CI = 1.51, 2.02) were significantly associated with bacterial indoor air quality. Relative humidity of treatment rooms (AOR = 1.87, p = 0.02, and 95% CI = 1.21, 3.09) had an association with bacterial loads. The clinic treatment rooms with a recorded temperature <25 °C (AOR = 6.32, p = 0.01, and 95% CI = 6.10, 8.25) had associated with fungal loads. But the rooms having a temperature of >28 °C (AOR = 0.41, p = 0.04, and 95% CI = 0.31, 0.78) were 59% less likely to comply with the fungal standards compared to rooms having a temperature of 25-28 °C. The clinic rooms with a relative humidity of <30% (AOR = 7.75, p = 0.02, 95% CI = 7.21, 8.39) were 7.75 times more likely to comply with those with a relative humidity of > 60% in the treatment rooms. CONCLUSION: Private clinics in Harar had a moderate fungal load and a higher indoor air bacterial concentration when compared to different indoor air standards. Temperature, humidity, inadequate ventilation and the presence of unsanitary attached toilets are some variables associated with microbial loads.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。