Reproducibility of proton density fat fraction assessment of thigh muscle in a multi-site, multi-vendor cohort study at 10 years after anterior cruciate ligament reconstruction

一项多中心、多厂商队列研究评估了前交叉韧带重建术后10年大腿肌肉质子密度脂肪分数评估的重复性

阅读:1

Abstract

BACKGROUND: Dixon-based magnetic resonance imaging (MRI) intramuscular proton density fat fraction (PDFF) is a potentially useful imaging biomarker of muscle quality. However, multi-vendor, multi-site reproducibility of intramuscular PDFF quantification, required for large clinical studies, can be strongly dependent on acquisition and processing. The purpose of this study was (I) to develop a 6-point Dixon MRI-based acquisition and processing technique for reproducible multi-vendor, multi-site quantification of thigh intramuscular PDFF; and (II) to evaluate the ability of the technique to detect differences in thigh muscle status between operated vs. non-operated limbs in a multi-site study of patients scanned at 10 years after anterior cruciate ligament reconstruction (ACLR). METHODS: MRI bilateral mid-thigh data acquisition at 3T was harmonized across three sites and two vendors and included high-resolution axial T1-weighted scans and 6-point Dixon scans. Centralized, vendor-independent PDFF quantification was performed and algorithms were evaluated in phantoms to determine the most reproducible approach. A novel image post-processing method was developed to mitigate scaling errors observed on some scanner platforms to improve reproducibility. PDFF measurements in phantoms and control subjects including traveling controls were obtained for assessment of intra-scanner repeatability as well as inter-scanner, inter-vendor, and inter-site reproducibility. Patients from the Multicenter Orthopedic Outcomes Network ACLR cohort were scanned and intramuscular PDFF was compared between thigh muscles of the operated and contralateral limbs. Standard deviation (SD) of PDFF, within-subject SD (wSD), and intraclass correlation coefficient (ICC) were used to characterize repeatability and reproducibility. RESULTS: The proposed scaling correction method improved overall reproducibility in phantoms and traveling controls and was incorporated as part of the Dixon processing pipeline for subsequent analyses. Intra-scanner phantom repeatability ranged between 0.2-0.9% (SD) PDFF (ICC =0.98-1.00), with overall inter-vendor/inter-site reproducibility of 0.7-1.7% (SD) PDFF (ICC =0.97). Control subject repeatability among all scanners and vendors ranged between 0.2-0.8% (wSD) PDFF (ICC =0.95-0.98) with slightly lower inter-site, inter-vendor reproducibility, 0.8-1.2% (wSD) PDFF (ICC =0.92). Intramuscular PDFF was elevated in ACLR vs contralateral thighs for the hamstrings muscle compartment (6.2%±3.5% vs. 5.7%±2.8%, P=0.006), while quadriceps (4.0%±2.0% vs. 4.0%±2.1%, P=0.961) and medial (5.7%±2.5% vs. 5.5%±2.3%, P=0.133) muscle compartments did not show significant PDFF differences. CONCLUSIONS: Reproducible multi-site, multi-vendor intramuscular PDFF measurement is enabled by 6-point Dixon MRI with standardized acquisition and processing. The method is sensitive enough to detect differences in muscle groups between operated and non-operated thighs in the patient population 10 years after ACLR.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。