Perioperative estimations of oxygen consumption from LiDCO™plus-derived cardiac output and Ca-cvO2 difference: Relationship with measurements by indirect calorimetry in elderly patients undergoing major abdominal surgery

利用LiDCO™plus衍生的心输出量和Ca-cvO2差值估算围手术期氧耗量:与老年患者接受大型腹部手术时间接测热法测量结果的关系

阅读:1

Abstract

BACKGROUND: Feasible estimations of perioperative changes in oxygen consumption (VO2) could enable larger studies of its role in postoperative outcomes. Current methods, either by reverse Fick calculations using pulmonary artery catheterisation or metabolic by breathing gas analysis, are often deemed too invasive or technically requiring. In addition, reverse Fick calculations report generally lower values of oxygen consumption. METHODS: We investigated the relationship between perioperative estimations of VO2 (EVO2), from LiDCO™plus-derived (LiDCO Ltd, Cambridge, UK) cardiac output and arterial-central venous oxygen content difference (Ca-cvO2), with indirect calorimetry (GVO2) by QuarkRMR (COSMED srl. Italy), using data collected 2017-2018 during a prospective observational study on perioperative oxygen transport in 20 patients >65 years during epidural and general anaesthesia for open pancreatic or liver resection surgery. Eighty-five simultaneous intra- and postoperative measurements at different perioperative stages were analysed for prediction, parallelity and by traditional agreement assessment. RESULTS: Unadjusted bias between GVO2 and EVO2 indexed for body surface area was 26 (95% CI 20 to 32) with limits of agreement (1.96SD) of -32 to 85 ml min-1m-2. Correlation adjusted for the bias was moderate, intraclass coefficient(A,1) 0.51(95% CI 0.34 to 0.65) [F (84,84) = 3.07, P<0.001]. There was an overall association between GVO2 and EVO2, in a random coefficient model [GVO2 = 73(95% CI 62 to 83) + 0.45(95% CI 0.29 to 0.61) EVO2 ml min-1m-2, P<0.0001]. GVO2 and EVO2 changed in parallel intra- and postoperatively when normalised to their respective overall means. CONCLUSION: Based on this data, estimations from LiDCO™plus-derived cardiac output and Ca-cvO2 are not reliable as a surrogate for perioperative VO2. Results were in line with previous studies comparing Fick-based and metabolic measurements but limited by variability of data and possible underpowering. The parallelity at different perioperative stages and the prediction model can provide useful guidance and methodological tools for future studies on similar methods in larger samples.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。