Mechanical study of the application of compression screw nails in the cross-inverted triangular pattern for internal fixation of femoral neck fractures

股骨颈骨折内固定中采用交叉倒三角形加压螺钉钉的力学研究

阅读:1

Abstract

OBJECTIVE: To design a cross-inverted triangular pattern to insert compression screw nails for the treatment of femoral neck fractures and to compare the biomechanics of inserting compression screw nails in cross-inverted triangular patterns and inverted triangular patterns. I am very sorry that a corresponding author needs to be added to the article. I do not know how to insert it, so I make a note here. Please check the attachment I uploaded. METHODS: The reasonableness of the model is first analyzed using finite elements. A total of 6 adult human specimens were selected, of which 3 males and 3 females were divided into the A1, B1, and C1 groups and the A2, B2, and C2 groups by the random number table method. The A1 and A2 groups were made into subhead femoral neck fracture models, the B1 and B2 groups were made into trans-neck femoral neck fracture models, and the C1 and C2 groups were made into basal femoral neck fracture models. The right femur of each group had a compression screw nail inserted in the crossed-inverted triangular pattern, and the left femur of each group had a compression screw nail inserted in the inverted triangular pattern. The static compression test was performed by an electronic universal testing machine. The maximum load of the femoral neck and the load of 3.00 mm axial displacement of the femoral head were read according to the pressure-displacement curve drawn in the experiment. RESULTS: The finite element analysis showed that the cross-inverted triangular hollow threaded nail has better conductivity and more stable fixation than the inverted triangular hollow threaded nail. The maximum load of the femoral neck and the load of 3.00 mm axial displacement of the femoral head of the left femur were greater than those of the right femur in the A1, A2, B1, B2 and C2 groups, while the maximum load of the femoral neck and the load of 3.00 mm axial displacement of the femoral head of the left femur were smaller than those of the right femur in the C1 group. There was no statistically significant difference in the maximum load of the femoral neck or the load of 3.00 mm axial displacement of the femoral head between the A1 and A2 groups, the B1 and B2 groups, or the C1 and C2 groups (P > 0.05). After the K-S test, the maximum load of the femoral neck and the load of 3.00 mm axial displacement of the femoral head were normally distributed (P = 0.20), and the LSD-t test was conducted for the two load data; the difference was not statistically significant (P = 0.235). CONCLUSION: The effect of compression screw nails in the cross-inverted triangular pattern was the same in males and females, and stability was better in the fixation of subhead and trans-neck femoral neck fractures. However, its stability in fixation of basal femoral neck fracture is worse than that of the inverted triangular pattern. The cross-inverted triangular hollow threaded nail has better conductivity and more stable fixation than the inverted triangular hollow threaded nail.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。