Impact of keel saw blade design and thickness on the incidence of tibial plateau fracture and tibial implant-loosening in cementless medial UKR

龙骨锯片设计和厚度对无骨水泥内侧单髁置换术中胫骨平台骨折和胫骨假体松动发生率的影响

阅读:2

Abstract

BACKGROUND: Tibial plateau fractures and tibial implant- loosening are severe complications in cementless unicompartmental knee replacement (UKR). The tibial keel preparation is particularly demanding and different saw blades can be used. It was hypothesized that different blade designs and thickness have an influence on the frequency of tibial plateau fractures and implant-loosening in cementless medial UKR. METHODS: 1258 patients with cementless medial UKR were included in this retrospective study between 2013 and 2020. The tibial keel cut was performed either with a double keel saw blade (DKS; 2.8 mm) and added hand guided pick or a mono reciprocating saw blade (RKB) of different thickness (2.5 mm; 2.65 mm; 2.75 mm). Tibial plateau fracture and loosening were demonstrated by standard two-plane radiographs. Tibial implant-loosening was defined as complete radiolucency and implant migration. Fracture and loosening were combined with pain and loss of function. RESULTS: In 126 patients (10%) the tibial keel was prepared with DKS, in 407 patients (32.4%) with RKB 2.5 mm, in 330 patients (26.2%) with RKB 2.65 mm and in 395 patients (31.4%) with 2.75 mm. In 4 patients (3.17%) with DKS tibial plateau fracture occurred, in 4 patients (0.99%) with 2.5 mm RKB, in 3 patients (0.92%) with 2.65 mm RKB and in 1 patient (0.25%) with 2.75 mm RKB. Significantly fewer fractures occurred with a RKB design (p = 0.007). A negative correlation between fracture incidence and RKB saw blade thickness was found (Spearman-r = - 0.93). No difference for tibial implant-loosening was shown (p = 0.51). CONCLUSION: Different blade designs and thickness have a significant influence on the incidence of tibial plateau fractures and aseptic tibial implant-loosening. The incidence of tibial plateau fractures in cementless medial UKR can be reduced by changing the design and thickness of the tibial keel saw blade. Greater thickness of RKB leads to significantly fewer tibial plateau fractures while the incidence of implant-loosening is not increasing. TRIAL REGISTRATION: This study was retrospectively registered and ethical approval was waived by the local ethical committee (No. 2020-1174).

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。