Six-Lead Electrocardiography Enables Identification of Rhythm and Conduction Anomalies of Patients in the Telemedicine-Based, Hospital-at-Home Setting: A Prospective Validation Study

六导联心电图能够识别远程医疗居家医院环境下患者的心律和传导异常:一项前瞻性验证研究

阅读:1

Abstract

BACKGROUND: The hospital-at-home (HAH) model is a viable alternative for conventional in-hospital stays worldwide. Serum electrolyte abnormalities are common in acute patients, especially in those with many comorbidities. Pathologic changes in cardiac electrophysiology pose a potential risk during HAH stays. Periodical electrocardiogram (ECG) tracing is therefore advised, but few studies have evaluated the accuracy and efficiency of compact, self-activated ECG devices in HAH settings. This study aimed to evaluate the reliability of such a device in comparison with a standard 12-lead ECG. METHODS: We prospectively recruited consecutive patients admitted to the Sheba Beyond Virtual Hospital, in the HAH department, during a 3-month duration. Each patient underwent a 12-lead ECG recording using the legacy device and a consecutive recording by a compact six-lead device. Baseline patient characteristics during hospitalization were collected. The level of agreement between devices was measured by Cohen's kappa coefficient for inter-rater reliability (Ϗ). RESULTS: Fifty patients were included in the study (median age 80 years, IQR 14). In total, 26 (52%) had electrolyte disturbances. Abnormal D-dimer values were observed in 33 (66%) patients, and 12 (24%) patients had elevated troponin values. We found a level of 94.5% raw agreement between devices with regards to nine of the options included in the automatic read-out of the legacy device. The calculated Ϗ was 0.72, classified as a substantial consensus. The rate of raw consensus regarding the ECG intervals' measurement (PR, RR, and QT) was 78.5%, and the calculated Ϗ was 0.42, corresponding to a moderate level of agreement. CONCLUSION: This is the first report to our knowledge regarding the feasibility of using a compact, six-lead ECG device in the setting of an HAH to be safe and bearing satisfying agreement level with a legacy, 12-lead ECG device, enabling quick, accessible arrythmia detection in this setting. Our findings bear a promise to the future development of telemedicine-based hospital-at-home methodology.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。