How many are we missing with ID NOW COVID-19 assay using direct nasopharyngeal swabs? Findings from a mid-sized academic hospital clinical microbiology laboratory

使用直接鼻咽拭子进行 ID NOW COVID-19 检测,我们漏检了多少病例?来自一家中型教学医院临床微生物实验室的研究结果

阅读:1

Abstract

Here, we retrospectively analyzed the comparative results of 182 paired dry nasopharyngeal swabs tested by Abbott ID NOW and nasopharyngeal swabs in viral transport medium by real-time RT-PCR methods. While the overall agreement was 96.2%, we found that of 15 samples that were tested positive with RT-PCR methods, 7 were missed by ID NOW, resulting in a false-negative rate of 47%.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。