Diagnostic performance of a high-spatial-resolution voxelwise analysis of neuromelanin-sensitive imaging in early-stage idiopathic Parkinson's disease

高空间分辨率体素级分析神经黑色素敏感成像在早期特发性帕金森病诊断中的性能

阅读:2

Abstract

BACKGROUND: Quantitative assessments of neuromelanin (NM) of the substantia nigra pars compacta (SNpc) in neuromelanin-sensitive MRI (NM-MRI) to determine its abnormality have been conducted by measuring either the volume or contrast ratio (CR) of the SNpc. A recent study determined the regions in the SNpc that are significantly different between early-stage idiopathic Parkinson's disease (IPD) patients and healthy controls (HCs) using a high spatial-resolution NM-MRI template, which enables a template-based voxelwise analysis to overcome the susceptibility of CR measurement to inter-rater discrepancy. We aimed to assess the diagnostic performance, which has not been reported, of the CRs between early-stage IPD patients and HCs using a NM-MRI template. METHODS: We retrospectively enrolled early-stage IPD patients (n = 50) and HCs (n = 50) who underwent 0.8-mm isovoxel NM-MRI and dopamine-transporter PET as the standard of reference. A template-based voxelwise analysis revealed two regions in nigrosomes 1 and 2 (N1 and N2, respectively), with significant differences in each substantia nigra (SNpc) between IPD and HCs. The mean CR values of N1, N2, volume-weighted mean of N1 and N2 (N1 + N2), and whole SNpc on each side were compared between IPD and HC using the independent t-test or the Mann-Whitney U test. The diagnostic performance was compared in each region using receiver operating characteristic curves. RESULTS: The mean CR values in the right N1 (0.149459 vs. 0.194505), left N1 (0.133328 vs. 0.169160), right N2 (0.230245 vs. 0.278181), left N2 (0.235784 vs. 0.314169), right N1 + N2 (0.155322 vs. 0.278143), left N1 + N2 (0.140991 vs. 0.276755), right whole SNpc (0.131397 vs. 0.141422), and left whole SNpc (0.127099 vs. 0.137873) significantly differed between IPD patients and HCs (all p < 0.001). The areas under the curve of the left N1 + N2, right N1 + N2, left N1, right N1, left N2, right N2, left whole SNpc, and right whole SNpc were 0.994 (sensitivity, 98.0%; specificity, 94.0%), 0.985, 0.804, 0.802, 0.777, 0.766, 0.632, and 0.606, respectively. CONCLUSION: Our NM-MRI template-based CR measurements revealed significant differences between early-stage IPD patients and HCs. The CR values of the left N1 + N2 demonstrated the highest diagnostic performance.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。