Axial and frontal X-ray fluoroscopy technique of the sustentaculum tali can improve the accuracy of sustentacular screw placement

距骨载距突的轴位和正位X线透视技术可以提高载距突螺钉置入的准确性。

阅读:1

Abstract

INTRODUCTION: Calcaneal fractures, especially those involving the articular surface, should be anatomically reduced as much as possible. Fixing the fracture by placing a screw into the sustentaculum tali from the lateral side of the calcaneus is generally considered to be the key to successful surgery. However, due to the limited visibility during surgery, it is not easy to place screws into the sustentaculum tali accurately. The purpose of this study was to explore a new fluoroscopy method for the sustentaculum tali and verify the value of this method in improving screw placement accuracy. METHODS: In this study, a total of 42 human foot and ankle specimens were dissected and measured. The shape and position of the sustentaculum tali were observed, and the influence of adjacent bones on imaging findings was analysed. The axial and frontal X-ray fluoroscopy method to view the sustentaculum tali was formulated, and the appropriate projection angle through anatomical and image measurements was explored. Thirty specimens were randomly selected for screw placement, and the direction of the screw was dynamically adjusted under the new imaging method. The success rate of sustentacular screw placement was evaluated. RESULTS: The anteversion angles of the sustentaculum tali were 30.81 ± 2.21° and 30.68 ± 2.86° by anatomical and imaging measurements, respectively. There was no statistically significant difference in the anteversion angle between the two measurement methods. Harris heel views should be obtained at 30° to identify the sustentaculum tali on axial X-ray images. Frontal X-ray imaging was performed perpendicular to this projection angle. Through frontal and axial X-ray imaging, the position and shape of the sustentaculum tali can be clearly observed, and these factors are seldom affected by adjacent bones. Under the new fluoroscopy method, the screws were placed from the anterior region of the lateral wall of the calcaneus to the sustentaculum tali. A total of 60 screws were placed in the 30 specimens; of these, 54 screws were in good position, 2 screws penetrated the cortical bone, and 4 screws did not enter the sustentaculum tali. The success rate of sustentacular screw placement was 90% (54/60). CONCLUSIONS: Axial and frontal X-ray images of the sustentaculum tali can clearly show the shape of the structure, which improves sustentacular screw placement accuracy.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。