Background
Hepatitis B virus (HBV) pregenomic RNA (pgRNA) has gained increasing attention owing to its role in replication of covalently closed circular DNA (cccDNA) in HBV. This marker has the potential to be used in clinical programs aimed to manage HBV infections. However, several reports on HBV pgRNA levels in clinical cases have conflicting
Conclusion
The plasma HBV pgRNA level was stable at 4 °C and at room temperature for at least 48 h and under multiple freeze-thaw cycles. Our results suggest that pgRNA is stable during the process of blood collection, and therefore results of pgRNA quantification are reliable.
Results
The mean HBV pgRNA level in the initially collected plasma samples was 5.58 log10copies/mL (ranging from 3.08 to 8.04 log10 copies/mL). The mean pgRNA levels in samples stored for different time periods compared with the initial reference sample (time 0) significantly decreased. The levels of pgRNA for 6, 12, 24, and 48 h of storage reduced by -0.05 log10 copies/mL (95% confidence interval (CI) -0.095 to -0.005, p = 0.03), -0.075 log10 copies/mL (95% CI [-0.12 to -0.03], p = 0.001), -0.084 log10 copies/mL (95% CI [-0.13 to -0.039], p = < 0.001), and -0.120 log10 copies/mL (95% CI [-0.17 to -0.076], p = < 0.001), respectively. However, these changes were below 0.5 log10 copies/mL and thus were not clinically significant. Compared with the samples stored at 4 °C, there were no significant differences in pgRNA levels in samples stored at 25 °C for any of the storage durations (-0.01 log10 copies/mL; 95% CI [-0.708 to 0.689], p = 0.98). No significant difference in the levels of pgRNA was observed in the plasma samples, following four freeze-thaw cycles at -20 °C and -80 °C.