13C15N: glucagon-based novel isotope dilution mass spectrometry method for measurement of glucagon metabolism in humans

13C15N:基于胰高血糖素的新型同位素稀释质谱法测量人体胰高血糖素代谢

阅读:5
作者:Santosh Renuse, Linda M Benson, Patrick M Vanderboom, F N U Ruchi, Yogesh R Yadav, Kenneth L Johnson, Benjamin C Brown, Jane A Peterson, Rita Basu, Daniel J McCormick, Akhilesh Pandey, Ananda Basu

Background

Glucagon serves as an important regulatory hormone for regulating blood glucose concentration with tight feedback control exerted by insulin and glucose. There are critical gaps in our understanding of glucagon kinetics, pancreatic α cell function and intra-islet feedback network that are disrupted in type 1 diabetes. This is important for translational research applications of evolving dual-hormone (insulin + glucagon) closed-loop artificial pancreas algorithms and their usage in type 1 diabetes. Thus, it is important to accurately measure glucagon kinetics in vivo and to develop robust models of glucose-insulin-glucagon interplay that could inform next generation of artificial pancreas algorithms.

Conclusions

The methods described in this study for simultaneous detection and quantitation of glucagon tracers have clinical utility for investigating glucagon kinetics in vivo in humans.

Methods

Here, we describe the administration of novel 13C15N heavy isotope-containing glucagon tracers-FF glucagon [(Phe 6 13C9,15N; Phe 22 13C9,15N)] and FFLA glucagon [(Phe 6 13C9,15N; Phe 22 13C9,15N; Leu 14 13C6,15N; Ala 19 13C3)] followed by anti-glucagon antibody-based enrichment and LC-MS/MS based-targeted assays using high-resolution mass spectrometry to determine levels of infused glucagon in plasma samples. The optimized assay

Results

The limit of quantitation was found to be 1.56 pg/ml using stable isotope-labeled glucagon as an internal standard. Intra and inter-assay variability was < 6% and < 16%, respectively, for FF glucagon while it was < 5% and < 23%, respectively, for FFLA glucagon. Further, we carried out a novel isotope dilution technique using glucagon tracers for studying glucagon kinetics in type 1 diabetes. Conclusions: The methods described in this study for simultaneous detection and quantitation of glucagon tracers have clinical utility for investigating glucagon kinetics in vivo in humans.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。