Evaluation of Blend Uniformity and Terminal Point during Continuous Mixing in Water for Modified Double-Base Propellant Components Using a Near-Infrared Method

使用近红外方法评估改性双基推进剂组分在水中连续混合过程中的混合均匀性和终点

阅读:4
作者:Ben Liu, Lei Xiao, Zongkai Wu, Duo Li, Yubing Hu, Guangpu Zhang, Fengqi Zhao, Xiuduo Song, Wei Jiang, Gazi Hao

Abstract

A near-infrared (NIR) spectrometer was used to test the double-base absorbent powder sample and to quantitatively analyze the contents of each component as well as their dispersion uniformity to establish a rapid quantitative test method for blending uniformity of modified double-base (MDB) propellant components. First, the quantitative calibration models of hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) were constructed based on sample testing, and the RDX model's correlation coefficient was 0.9929. Then, during the blending process, NIR spectra were continually collected. For the original spectra of samples, the blend uniformity was assessed using the coefficient of moving block standard deviation (MBSD). After 160 min, the sample's MBSD value had reached a steady state of less than 0.003, indicating that the sample's components were distributed uniformly. The findings reveal that NIR spectroscopy can be used to verify the blending uniformity of MDB propellant components.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。