Reliability of Potential Pain Biomarkers in the Saliva of Healthy Subjects: Inter-Individual Differences and Intersession Variability

健康受试者唾液中潜在疼痛生物标志物的可靠性:个体间差异和治疗间变异性

阅读:5
作者:Eva M Sobas, Roberto Reinoso, Rubén Cuadrado-Asensio, Itziar Fernández, Miguel J Maldonado, José C Pastor

Aim

Salivary cortisol, α-amylase (sAA), secretory IgA (sIgA), testosterone, and soluble fraction of receptor II of TNFα (sTNFαRII) could serve as objective pain measures, but the normal variability of these potential biomarkers is unknown. Patients &

Conclusions

Salivary sIgA and sTNFαRII show a remarkable good reproducibility and, therefore, could be useful as pain biomarkers. When using the passive secretion method, intersession variations in salivary sIgA of more than 11.7 μg/ml may reflect true biomarker change. In the case of sTNFαRII this will depend of the magnitude. The estimates herein provided should help investigators and clinicians differentiate actual biomarker modification from measurement variability.

Methods

Saliva was collected with the passive secretion method from 34, pain-free subjects in two single samples at least 24 hours apart. Biomarker variation and intersession reliability were assessed with the intraclass correlation coefficient (ICC). Also, we calculated the within-subject standard deviation (Sw) and the reproducibility (2.77 × Sw) of intersession measures.

Results

Salivary cortisol, sAA, sIgA, testosterone, and sTNFαRII yielded the following ICCs: 0.53, 0.003, 0.88, 0.42 and 0.83, respectively. We found no statistically significant systematic differences between sessions in any biomarker except for testosterone, which showed a decrease on the second day (p<0.001). The reproducibility for salivary cortisol, sAA, sIgA, testosterone, and sTNFαRII were 0.46 ng/ml, 12.88 U/ml, 11.7 μg/ml, 14.54 pg/ml and 18.29 pg/ml, respectively. Cortisol, testosterone and TNFαRII measurement variability showed a positive correlation with the magnitude (p<0.002), but no relationship was found for sAA and sIgA. Conclusions: Salivary sIgA and sTNFαRII show a remarkable good reproducibility and, therefore, could be useful as pain biomarkers. When using the passive secretion method, intersession variations in salivary sIgA of more than 11.7 μg/ml may reflect true biomarker change. In the case of sTNFαRII this will depend of the magnitude. The estimates herein provided should help investigators and clinicians differentiate actual biomarker modification from measurement variability.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。