Enhancing Nutrition Care Through Real-Time, Sensor-Based Capture of Eating Occasions: A Scoping Review

通过实时、基于传感器的进食场景采集来提升营养护理:一项范围界定综述

阅读:1

Abstract

As food intake patterns become less structured, different methods of dietary assessment may be required to capture frequently omitted snacks, smaller meals, and the time of day when they are consumed. Incorporating sensors that passively and objectively detect eating behavior may assist in capturing these eating occasions into dietary assessment methods. The aim of this study was to identify and collate sensor-based technologies that are feasible for dietitians to use to assist with performing dietary assessments in real-world practice settings. A scoping review was conducted using the PRISMA extension for scoping reviews (PRISMA-ScR) framework. Studies were included if they were published between January 2016 and December 2021 and evaluated the performance of sensor-based devices for identifying and recording the time of food intake. Devices from included studies were further evaluated against a set of feasibility criteria to determine whether they could potentially be used to assist dietitians in conducting dietary assessments. The feasibility criteria were, in brief, consisting of an accuracy ≥80%; tested in settings where subjects were free to choose their own foods and activities; social acceptability and comfort; a long battery life; and a relatively rapid detection of an eating episode. Fifty-four studies describing 53 unique devices and 4 device combinations worn on the wrist (n = 18), head (n = 16), neck (n = 9), and other locations (n = 14) were included. Whilst none of the devices strictly met all feasibility criteria currently, continuous refinement and testing of device software and hardware are likely given the rapidly changing nature of this emerging field. The main reasons devices failed to meet the feasibility criteria were: an insufficient or lack of reporting on battery life (91%), the use of a limited number of foods and behaviors to evaluate device performance (63%), and the device being socially unacceptable or uncomfortable to wear for long durations (46%). Until sensor-based dietary assessment tools have been designed into more inconspicuous prototypes and are able to detect most food and beverage consumption throughout the day, their use will not be feasible for dietitians in practice settings.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。