Between-Session Reliability of Field-Based Assessments of Isometric Neck Strength

基于现场的等长颈部力量评估的会间信度

阅读:1

Abstract

The reliability of the fixed-frame dynamometer for measuring isometric neck strength is established, but with limited field-based applications. This study aimed to establish the inter- and intra-session reliability of the peak force for neck flexors, extensors, and side flexors using the VALD ForceFrame and DynaMo and the force-time characteristics in the quadruped position (ForceFrame). Twenty-seven recreationally active males performed three repetitions of isometric neck flexion, extension, and side flexion over two sessions in random order using the VALD ForceFrame and DynaMo. Both devices demonstrated acceptable reliability, with the Forceframe ICC > 0.8 and CV% < 13.8% and the DynaMo ICC > 0.76 and CV% < 13.8%. No systematic or proportional differences were found using the Passing-Bablock procedure, and Bland-Altman analysis confirmed agreement across measures. Reliability was shown for right-side (ICC > 0.76) and left-side (ICC > 0.79) flexion and flexion (ICC > 0.75) across 50, 100, 150, and 200 ms. Statistical parametric mapping indicated no differences in ForceFrame-generated isometric force-time curves between sessions, though the CV was highest in the force development phase. The findings suggest that both tools can reliably assess neck strength, supporting their use in sports and clinical settings. However, assessment methods are not interchangeable, emphasising the need for standardised neck strength assessment approaches.