Integrin-targeted quantitative optoacoustic imaging with MRI correlation for monitoring a BRAF/MEK inhibitor combination therapy in a murine model of human melanoma

整合素靶向定量光声成像与 MRI 相关性用于监测人类黑色素瘤小鼠模型中的 BRAF/MEK 抑制剂联合治疗

阅读:15
作者:Philipp M Kazmierczak, Neal C Burton, Georg Keinrath, Heidrun Hirner-Eppeneder, Moritz J Schneider, Ralf S Eschbach, Maurice Heimer, Olga Solyanik, Andrei Todica, Maximilian F Reiser, Jens Ricke, Clemens C Cyran

Conclusions

αvβ3-integrin-targeted optoacoustic imaging allowed for the early non-invasive monitoring of a BRAF/MEK inhibitor combination therapy in a murine model of human melanoma, adding molecular information on tumor receptor status to morphology-based tumor response criteria.

Methods

Human BRAF V600E-positive melanoma xenograft (A375)-bearing Balb/c nude mice (n = 10) were imaged before (day 0) and after (day 7) a BRAF/MEK inhibitor combination therapy (encorafenib, 1.3 mg/kg/d; binimetinib, 0.6 mg/kg/d, n = 5) or placebo (n = 5), respectively. Optoacoustic imaging was performed on a preclinical system unenhanced and 5 h after i. v. injection of an αvβ3-integrin-targeted fluorescent probe. The αvβ3-integrin-specific tumor signal was derived by spectral unmixing. For morphology-based tumor response assessments, T2w MRI data sets were acquired on a clinical 3 Tesla scanner. The imaging

Purpose

To investigate αvβ3-integrin-targeted optoacoustic imaging and MRI for monitoring a BRAF/MEK inhibitor combination therapy in a murine model of human melanoma. Materials and

Results

The αvβ3-integrin-specific tumor signal was significantly reduced under therapy, showing a unidirectional decline in all animals (from 7.98±2.22 to 1.67±1.30; p = 0.043). No significant signal change was observed in the control group (from 6.60±6.51 to 3.67±1.93; p = 0.500). Immunohistochemistry revealed a significantly lower integrin expression (ß3: 0.20±0.02 vs. 0.39±0.05; p = 0.008) and microvascular density (CD31: 119±15 vs. 292±49; p = 0.008) in the therapy group. Tumor volumes increased with no significant intergroup difference (therapy: +107±42 mm3; control +112±44mm3, p = 0.841). In vivo blocking studies with αvβ3-integrin antagonist cilengitide confirmed the target specificity of the fluorescent probe. Conclusions: αvβ3-integrin-targeted optoacoustic imaging allowed for the early non-invasive monitoring of a BRAF/MEK inhibitor combination therapy in a murine model of human melanoma, adding molecular information on tumor receptor status to morphology-based tumor response criteria.