Long-Acting Real-Time Microscopic Monitoring Inside the Proton Exchange Membrane Water Electrolyzer

质子交换膜水电解槽内部的长效实时显微监测

阅读:1

Abstract

The proton exchange membrane water electrolyzer (PEMWE) requires a high operating voltage for hydrogen production to accelerate the decomposition of hydrogen molecules so that the PEMWE ages or fails. According to the prior findings of this R&D team, temperature and voltage can influence the performance or aging of PEMWE. As the PEMWE ages inside, the nonuniform flow distribution results in large temperature differences, current density drops, and runner plate corrosion. The mechanical stress and thermal stress resulting from pressure distribution nonuniformity will induce the local aging or failure of PEMWE. The authors of this study used gold etchant for etching, and acetone was used for the lift-off part. The wet etching method has the risk of over-etching, and the cost of the etching solution is also higher than that of acetone. Therefore, the authors of this experiment adopted a lift-off process. Using the flexible seven-in-one (voltage, current, temperature, humidity, flow, pressure, oxygen) microsensor developed by our team, after optimized design, fabrication, and reliability testing, it was embedded in PEMWE for 200 h. The results of our accelerated aging test prove that these physical factors affect the aging of PEMWE.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。