Diagnostic Performance of Transient Elastography Versus Two-Dimensional Shear Wave Elastography for Liver Fibrosis in Chronic Viral Hepatitis: Direct Comparison and a Meta-Analysis

瞬时弹性成像与二维剪切波弹性成像在慢性病毒性肝炎肝纤维化诊断中的性能比较:直接比较和荟萃分析

阅读:2

Abstract

OBJECTIVE: This systematic review and meta-analysis aimed to compare the diagnostic performance of transient elastography (TE) and two-dimensional shear wave elastography (2D-SWE) for staging liver fibrosis in patients with chronic viral hepatitis (CVH). METHODS: Pubmed, Embase, Web of Science, and Cochrane Library were searched (-01/08/2021) for studies comparing TE with 2D-SWE in patients with CVH. Other etiologies of chronic liver disease (CLD) and articles not published in SCI journals were excluded. The bivariate random-effects model was used to pool the performance of the TE and 2D-SWE. RESULTS: Eight articles with a total of 1301 CVH patients were included. The prevalence of significant fibrosis (fibrosis stage ≥ 2), advanced fibrosis (fibrosis stage ≥ 3), and cirrhosis was 50.8%, 44.8%, and 34.7%, respectively. 2D-SWE expressed higher overall accuracy than TE in detecting significant fibrosis (0.93 vs. 0.85, P = 0.04). No significant difference among the overall diagnostic accuracy of TE and 2D-SWE in staging advanced fibrosis and cirrhosis was found. CONCLUSION: TE and 2D-SWE express good to excellent diagnostic accuracies to stage fibrosis in CVH patients. 2D-SWE compares favorably with TE especially for predicting significant fibrosis.