The plasma free fraction of 25-hydroxyvitamin D(3) is not strongly associated with 25-hydroxyvitamin D(3) clearance in kidney disease patients and controls

在肾病患者和对照组中,血浆游离25-羟基维生素D3浓度与25-羟基维生素D3清除率之间无显著相关性。

阅读:1

Abstract

Circulating 25-hydroxyvitamin D [25(OH)D] concentration is used to monitor vitamin D status. Plasma protein binding may influence the 25(OH)D dose-response to vitamin D treatment through a direct relationship between the plasma unbound ("free") fraction and clearance of 25(OH)D. We previously evaluated 25(OH)D(3) clearance in relation to kidney function using intravenous administration of deuterium labeled 25(OH)D(3). In this follow up study, we determined the free fraction of 25(OH)D(3) in plasma (i.e., percent free 25(OH)D(3)) and the serum concentration and haplotype of vitamin D binding protein in these participants. We hypothesized that the percent free 25(OH)D(3) would be positively associated with 25(OH)D(3) clearance and would mediate associations between clearance and vitamin D binding protein (GC) haplotypes. Participants were mean (SD) age 64 (10) years and included 42 individuals with normal kidney function (controls), 24 individuals with chronic kidney disease, and 19 individuals with kidney failure on hemodialysis. Free plasma 25(OH)D(2) and 25(OH)D(3) concentrations were quantified with a new liquid chromatography-tandem mass spectrometry (LC-MS/MS) method. Because there is no reference measurement procedure for free 25(OH)D, we compared the new method with a widely-used predictive equation and a commercial immunoassay. The percent free 25(OH)D(3) determined by predictive equation was weakly associated with 25(OH)D(3) clearance (R = 0.27; P = 0.01). However, this association was absent when percent free 25(OH)D(3) was determined using LC-MS/MS-measured free and total 25(OH)D(3) concentrations. Method comparison uncovered a negative bias in immunoassay-measured free 25(OH)D concentrations among participants with kidney failure, so immunoassay results were not used to evaluate the association between percent free 25(OH)D(3) and clearance. GC2 haplotype carriage was associated with 25(OH)D(3) clearance. Among individuals with 2 relative to no GC2 alleles, clearance was 87 (95% CI: 15-158) mL/d greater. However, in contrast with the literature, GC2 carriage was not significantly related to DBP concentration or the percent free 25(OH)D(3) (either predicted or measured). In conclusion, the free fraction of 25(OH)D(3) is not strongly associated with 25(OH)D(3) clearance but may explain small differences in clearance according to GC haplotype.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。