A Suitable HPLC-MS/MS Methodology for the Detection of Oxytetracycline, Enrofloxacin, and Sulfachloropyridazine Residues in Lettuce Plants

一种适用于检测莴苣中土霉素、恩诺沙星和磺胺氯哒嗪残留量的 HPLC-MS/MS 方法

阅读:12
作者:Karina Yévenes, María José Ibáñez, Ekaterina Pokrant, Andrés Flores, Matías Maturana, Aldo Maddaleno, Javiera Cornejo

Abstract

Oxytetracycline (OTC), enrofloxacin (EFX), and sulfachloropyridazine (SCP) are critically important antimicrobials (AMs) in both human and veterinary medicine, where they are widely used in farm animals. Lettuce has become a matrix of choice for studying the presence of residues of these AMs in plants, as the concentrations of residues detected in lettuce can range from ng to mg. While several analytical methodologies have been developed for the purpose of detecting AMs in lettuce, these currently do not detect both the parent compound and its active metabolites or epimers, such as in the case of ciprofloxacin (CFX) and 4-epi-oxitetracycline (4-epi-OTC), which also pose a risk to public health and the environment due to their AM activity. In light of this situation, this work proposes an analytical method that was developed specifically to allow for the detection of OTC, 4-epi-OTC, EFX, CFX, and SCP in a lettuce matrix. This method uses acetonitrile, methanol, 0.5% formic acid, and McIlvaine-EDTA buffer as extraction solvents, and dispersive solid-phase extraction (dSPE) for the clean-up. The analytes were detected using a liquid chromatography technique coupled to mass spectrometry (HPLC-MS/MS). Parameters such as the specificity, linearity, recovery, precision, limit of detection, and limit (LOD) of quantification (LOQ) were calculated according to the recommendations established in the European Union decision 2021/808/EC and VICH GL2: Validation of analytical procedures. The LOQ for the analytes OTC, 4-epi-OTC, CFX, and SCP was 1 μg·kg-1, whereas for EFX, it was 5 μg·kg-1 dry weight. All calibration curves showed a coefficient of determination (R2) of >0.99. The recovery levels ranged from 93.0 to 110.5% and the precision met the acceptance criteria, with a coefficient of variation of ≤14.02%. Therefore, this methodology allows for the precise and reliable detection and quantification of these analytes. The analysis of commercial samples confirmed the suitability of this method.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。