Application of three-dimensional transesophageal echocardiography in preoperative evaluation of transcatheter aortic valve replacement

三维经食道超声心动图在经导管主动脉瓣置换术术前评估中的应用

阅读:2

Abstract

BACKGROUND: Our goal was to determine the accuracy of 3-dimensional transesophageal echocardiography (3D-TEE) compared with that of computed tomography (CT) in the preoperative evaluation for transcatheter aortic valve replacement (TAVR) when the errors caused by inconsistent software and method have been eliminated and the representativeness of the sample has been improved. We also investigated the influence of aortic root calcification on the accuracy of 3D-TEE in aortic annulus evaluations. METHODS: Part I: 45 of 233 patients who underwent TAVR in the department of cardiovascular surgery at the Xijing hospital from January 2016 to August 2019 were studied retrospectively. Materialise Mimics software and the multiplanar reconstruction method were used for evaluation, based on 3D-TEE and CT. The annulus area-derived diameter, the annulus perimeter-derived diameter (Dp), the annulus mean diameter, the left ventricular outflow tract Dp diameter, the sinotubular junction (STJ) diameter-Dp, and the aortic sinus diameter were compared and analyzed. Part II: 31 of 233 patients whose 3D-TEE and CT data were well preserved and in the required format were included. HU450 and HU850 were used as indicators to measure the severity of calcification. The Spearman rank correlation and Linear regression were used to analyze the correlation between aortic root calcification and the accuracy of 3D-TEE in aortic annulus measurement. RESULTS: The measurement results based on 3D-TEE were significantly lower than those obtained using CT (P < 0.05), except for the STJ diameter-Dp in diastole (P = 0.11). The correlation coefficient of the two groups was 0.699-0.954 (P < 0.01), which also indicated a significant correlation between the two groups. A Bland-Altman plot showed that the ordinate values were mostly within the 95% consistency limit; the consistency of the two groups was good. By establishing the linear regression equation, the two groups can be inferred from each other. The Spearman rank correlation analysis and the Linear regression analysis showed that the influence of aortic calcification on the accuracy of the 3D-TEE annulus evaluation was limited. CONCLUSIONS: Although an evaluation based on 3D-TEE underestimated the results, we can deduce CT results from 3D-TEE because the two methods exhibit considerable correlation and consistency. TRIAL REGISTRATION: Name: Surgery and Transcatheter Intervention for Structural Heart Diseases. Number: NCT02917980. URL: https://clinicaltrials.gov/ct2/results?term=NCT02917980 .

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。