Effect of filter extraction solvents on the measurement of the oxidative potential of airborne PM2.5

滤纸萃取溶剂对空气中 PM2.5 氧化电位测量的影响

阅读:11
作者:Maria Chiara Pietrogrande, Dimitri Bacco, Arianna Trentini, Mara Russo

Abstract

Solvent extraction of PM2.5 samples collected on the filter is a preliminary step for assessing the PM2.5 oxidative potential (OP) using cell-free assays, as the dithiothreitol (DTT) and the ascorbic acid (AA) assays. In this study, we evaluated the effect of the solvent choice by extracting ambient PM2.5 samples with different solvents: methanol, as organic solvent, and two aqueous buffers, i.e., phosphate buffer (PB) and Gamble's solution (G), as a lung fluid surrogate solution. Both the measured volume-based OPVDTT and OPVAA responses varied for the different extraction methods, since methanol extraction generated the lowest values and phosphate buffer the highest. Although all the tested solvents produced intercorrelated OPVDTT values, the phosphate buffer resulted the most useful for OPDTT assessment, as it provided the most sensible measure (nearly double values) compared with other extractions. The association of the measured OPV values with PM chemical composition suggested that oxidative properties of the investigated PM2.5 samples depend on both transition metals and quinones, as also supported by additional experimental measurements on standard solutions of redox-active species.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。