Four-dimensional Flow MRI-based Computational Fluid Dynamics Simulation for Noninvasive Portosystemic Pressure Gradient Assessment in Patients with Cirrhosis and Transjugular Intrahepatic Portosystemic Shunt

基于四维流动磁共振成像的计算流体动力学模拟用于无创评估肝硬化和经颈静脉肝内门体分流术患者的门体压力梯度

阅读:1

Abstract

Background Transjugular intrahepatic portosystemic shunt (TIPS) dysfunction in patients with liver cirrhosis and recurrent symptoms of portal hypertension is primarily assessed with US and confirmed with invasive catheter venography, which can be used to measure the portosystemic pressure gradient (PSPG) to identify TIPS-refractory portal hypertension. To avoid the risks and costs of invasive catheter venography, noninvasive PSPG evaluation strategies are needed. Purpose To demonstrate the feasibility of the combination of four-dimensional (4D) flow MRI with computational fluid dynamics (CFD) for noninvasive PSPG assessment in participants with cirrhosis and TIPS. Materials and Methods Abdominal 4D flow MRI was performed prospectively in participants with cirrhosis and TIPS between January 2019 and September 2020. Flow rates were measured within the TIPS and inferior vena cava (IVC). The portal vein (PV), TIPS, right hepatic vein, and IVC were segmented on MRI scans to create a CFD mesh. The PV and infrahepatic IVC were defined as inflows for 4D flow MRI-derived flow rates. The suprahepatic IVC was defined as the outflow. CFD simulations were used to noninvasively estimate PSPG as the difference between the simulated pressures in the PV and suprahepatic IVC. Invasive venographic measurements of the PSPG served as the reference standard, and Pearson correlation analysis was conducted to evaluate the relationship between noninvasive estimates and invasive measurements. Results In all 20 participants with cirrhosis (mean age, 58 years ± 9 [SD]; 11 men), 4D flow MRI-based CFD simulations enabled visualization of flow velocities and pressure distributions within the segmented vasculature and TIPS. Noninvasive estimates and invasive measures of PSPG were strongly correlated (r = 0.77; P < .001). The 4D flow MRI-based CFD simulations correctly classified the presence or absence of a post-TIPS PSPG greater than 12 mm Hg in 16 of 20 participants (80%). Conclusion The combination of 4D flow MRI and CFD was feasible for noninvasive PSPG assessment in participants with cirrhosis, portal hypertension, and TIPS. © RSNA, 2024 See also the editorial by Motosugi and Watanabe in this issue.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。