Detection of an internal density change in an anthropomorphic head phantom via tracking of charged nuclear fragments in carbon-ion radiotherapy

通过追踪碳离子放射治疗中带电核碎片来检测人体头部模型内部密度变化

阅读:1

Abstract

BACKGROUND: Carbon-ion radiotherapy provides steep dose gradients that allow the simultaneous application of high tumor doses as well as the sparing of healthy tissue and radio-sensitive organs. However, even small anatomical changes may have a severe impact on the dose distribution because of the finite range of ion beams. PURPOSE: An in-vivo monitoring method based on secondary-ion emission could potentially provide feedback about the patient anatomy and thus the treatment quality. This work aims to prove that a clinically relevant anatomical change in an anthropomorphic head phantom may be detected via charged-fragment tracking during a treatment fraction. METHODS: A clinically representative carbon-ion treatment plan was created for a skull-base tumor in an anthropomorphic head phantom. In order to imitate an inter-fractional anatomical change - for example, through tissue swelling or mucous accumulation - a piece of silicone was inserted into the nasopharynx. Fragment distributions with and without the silicone insert were subsequently acquired with a mini-tracker made of four hybrid silicon pixel detectors. Experimental irradiations were carried out at the Heidelberg Ion Beam Therapy Centre (HIT, Germany). FLUKA Monte Carlo simulations were performed to support the interpretation of the experimental results. RESULTS: It was found that the silicone causes a significant change in the fragment emission that was clearly distinguishable from statistical fluctuations and setup uncertainties. Two regions of fragment loss were observed upstream and downstream of the silicone with similar amplitude in both the measurement and the simulation. Monte Carlo simulations showed that the observed signature is a consequence of a complex interplay of fragment production, scattering, and absorption. CONCLUSIONS: Carbon-ion therapy monitoring with charged nuclear fragments was shown to be capable of detecting clinically relevant density changes in an anthropomorphic head phantom under realistic clinic-like conditions. The complexity of the observed signal requires the development of advanced analysis techniques and underscores the importance of Monte Carlo simulations. The findings have strong implications for the ongoing InViMo clinical trial at HIT, which investigates the feasibility of secondary-ion monitoring for skull-base cancer patients.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。