Patient-specific mapping of fundus photographs to three-dimensional ocular imaging

将眼底照片进行患者特异性映射,生成三维眼部图像

阅读:1

Abstract

BACKGROUND: Ocular proton beam therapy (OPT) planning would benefit from an accurate incorporation of fundus photographs, as various intra-ocular structures, such as the fovea, are not visible on conventional modalities such as Magnetic Resonance Imaging (MRI). However, the use of fundus photographs in OPT is limited, as the eye's optics induce a nonuniform patient-specific deformation to the images. PURPOSE: To develop a method to accurately map fundus photographs to three-dimensional images. METHODS: Personalized optical raytracing simulations were performed for 27 subjects, using subject-specific eye models based on corneal topography, biometry, and MRI. Light rays were traced through the eye for angles of 0°-85° with respect to the optical axis, in steps of 5°. These simulations provided a reference mapping between camera angles and retinal locations and were used to develop a mapping method without raytracing. The accuracy of this and earlier proposed methods was evaluated. Finally, the most accurate method was implemented in RayOcular, an image-based OPT planning system, and the fundus photography-based tumor contour was compared with MRI. RESULTS: When a patient-specific second nodal point is taken as a reference to describe the retinal location, the camera, and retinal angles show a strong linear relation with a small variation between subjects. At a camera angle of 60°, for example, a corresponding retinal angle of 59.9° ± 0.4° (mean ± SD) was found. When this linear relation is used to predict the corresponding retinal location (without raytracing) of a camera angle of 40°, the mean (Euclidian distance) error in the retinal location was 0.02 mm (SD = 0.06 mm), which was significantly (p < 0.001) lower than earlier proposed methods including EYEPLAN 4.16 mm (SD = 0.25 mm), the Lamberth projection -0.12 mm (SD = 0.46 mm) or polar projection 0.26 mm (SD = 0.57 mm). When implemented in the fundus view of RayOcular, the median distance between contours based on MRI and fundus photography was 0.2 mm (IQR = 0.1-0.3 mm). CONCLUSIONS: The second nodal point provides a patient-specific reference for an accurate mapping of fundus photographs to three-dimensional images with sub-millimeter errors.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。