Fluoroscopy-guided aspiration of the acutely dislocated total hip arthroplasty: a feasible, high-yield, and safe procedure

透视引导下急性髋关节置换术脱位抽吸:一种可行、高效且安全的手术方法

阅读:1

Abstract

OBJECTIVE: To determine the feasibility, yield, and safety of fluoroscopic-guided aspiration of the acutely dislocated total hip arthroplasty (AD-THA). MATERIALS AND METHODS: IRB-approved, retrospective review of fluoroscopic-guided aspirations of AD-THA (January 2005-December 2023) was performed. Data from electronic charts and fluoroscopy images/reports were obtained. Positive yield was defined as spontaneous aspirate or saline rinse adequate for microbiology analysis. Sub-analysis by needle target (acetabular cup or femur) was performed for spontaneous aspiration rate, aspirate volume and fluoroscopy time. Differences between groups were analyzed with unpaired, t-test (2-tail) and between proportions with Fisher's exact test, with significance p < 0.05. RESULTS: Aspiration of 20 AD-THA in 19 patients (12 female, mean age (SD) of 73 years (16)) targeted the acetabular cup in 45% (9/20) or femur in 55% (11/20) of cases. Positive yield was obtained in 95% (19/20), with spontaneous aspirate in 75% (15/20) and saline rinse in 20% (4/20) of cases; in 5% (1/20), no diagnostic sample was obtained. Spontaneous aspirate mean volume (SD, range) for all cases was 8.3 mL (6.9, 0.2-25), and higher when targeting the acetabular cup 11.2 mL (6.9, 5-25) versus the femur 4.0 mL (4.4, 0.2-12) (p = 0.026). The rate of spontaneous aspiration was higher for the acetabular cup 100% (9/9) versus the femur 55% (6/11) (p = 0.038). The mean fluoroscopy time (SD, range) for all cases was 43 s (25, 19-102), and shorter for targeting the acetabular cup 32 s (16, 19-75) versus the femur 56 s (28, 28-102) (p = 0.034). No immediate complications occurred in all aspirations. CONCLUSION: Fluoroscopy-guided aspiration of AD-THA is a feasible, high-yield, and safe procedure. Targeting the acetabular cup results in a higher rate of spontaneous aspirate, larger aspiration volume, and lower fluoroscopy time. CRITICAL RELEVANCE STATEMENT: Although technically more challenging, radiologists should feel confident aspirating the acutely dislocated total hip arthroplasty (AD-THA) under fluoroscopic guidance. KEY POINTS: Total hip arthroplasty (THA) infection can be evaluated with synovial fluid aspiration. Fluoroscopic-guided aspiration of the dislocated THA is feasible, high-yield, and safe. Targeting of the acetabular cup is recommended over the femoral prosthetic component. Acetabular cup targeting gives larger, spontaneous aspirates with lower fluoroscopy time.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。