Enhancing Wire-Rope Damage Signals Based on a Radial Magnetic Concentrator Bridge Circuit

基于径向磁集中桥电路的钢丝绳损伤信号增强

阅读:1

Abstract

Hall-effect sensors are used for the non-destructive testing of wire ropes owing to their low power consumption and high operation frequency. The high-speed operation of wire ropes causes vibration inclination at different frequencies, which makes it difficult to detect the ropes. Considering that the radial signal in the magnetic flux leakage (MFL) detection method can respond to damages to the maximum extent possible, this study proposes a radial magnetic concentrator suitable for the non-destructive testing of wire ropes based on theoretical analysis and transient magnetic field simulations. The concentrator improves the radial magnetic circuit, polymerizes the leakage of the magnetic field in the detection device, and the leakage of the magnetic field of the defect converges at the sensor position of the circumferential array to improve the signal-to-noise ratio of the Hall-effect sensor. In addition, the MFL field is homogenized through the structure of the magnetic concentrator when the wire rope is tilted, which weakens the influence of the vibration tilt of the wire rope on the test results. Finally, the experiments show that the amplitude of the wire-rope damage signal is effectively improved by using the proposed radial magnetic concentration technology, hence being convenient for defect analyses.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。