Middle molecule clearance with high cut-off dialyzer versus high-flux dialyzer using continuous veno-venous hemodialysis with regional citrate anticoagulation: A prospective randomized controlled trial

采用高截留透析器与高通量透析器进行连续静脉-静脉血液透析联合区域性枸橼酸抗凝治疗,对中分子清除率的影响:一项前瞻性随机对照试验

阅读:2

Abstract

BACKGROUND: Regional anticoagulation with citrate during renal replacement therapy (RRT) reduces the risk of bleeding, extends dialyzer lifespan and is cost-effective. Therefore, current guidelines recommend its use if patients are not anticoagulated for another reason and if there are no contraindications against citrate. RRT with regional citrate anticoagulation has been established in critically ill patients as continuous veno-venous hemodialysis (CVVHD) to reduce citrate load. However, CVVHD is inferior regarding middle molecule clearance compared to continuous veno-venous hemofiltration (CVVH). The use of a high cut-off dialyzer in CVVHD may thus present an option for middle molecule clearance similar to CVVH. This may allow combining the advantages of both techniques. METHODS: In this prospective, randomized, single-blinded single-center-trial, sixty patients with acute renal failure and established indication for renal replacement therapy were randomized 1:1 into two groups. The control group was put on CVVHD using regional citrate anticoagulation and a high-flux dialyzer, while the intervention group was on CVVHD using regional citrate anticoagulation and a high-cut-off dialyzer. The concentrations of urea, creatinine, β2-microglobulin, myoglobin, interleukin 6 and albumin were measured pre- and post-dialyzer 1, 6, 12, 24 and 48 hours after initiating CVVHD. RESULTS: Mean plasma clearance for β2-microglobulin was 19.6±5.8 ml/min in the intervention group vs. 12.2±3.6 ml/min in the control group (p<0.001). For myoglobin (8.0±4.5 ml/min vs. 0.2±3.6 ml/min, p<0.001) and IL-6 (1.5±4.3 vs. -2.5±3.5 ml/min, p = 0.002) a higher mean plasma clearance using high-cut-off dialyzer could be detected too, but no difference for urea, creatinine and albumin could be observed concerning this parameter between the two groups. CONCLUSION: CVVHD using a high cut-off dialyzer results in more effective middle molecule clearance than that with high-flux dialyzer. TRIAL REGISTRATION: German Clinical Trials Register (DRKS00005254, registered 26th November 2013).

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。