Verification of Angular Response of Sky Quality Meter with Quasi-Punctual Light Sources

利用准点光源验证天空质量测量仪的角度响应

阅读:1

Abstract

Sky Quality Meter (SQM) is a commercial instrument based on photometers widely used by amateur astronomers for skyglow measurement from the ground. In the framework of the MINLU project, two SQM-LE units were integrated in an autonomous sensor suite realized and tested at University of Padova for monitoring light pollution from drones or sounding balloons. During the ground tests campaign before airborne measurement, the performance of both SQM units was verified in laboratory using controlled light sources as a reference input; the results showed that both units presented an angular response deviating consistently from the expected performance and that the sensors' field of view was larger than the one declared in the manufacturer's datasheet. This aspect in particular would affect direct skyglow measurements during flight as light sources close to the boundaries of the field of view would not be attenuated but instead detected by the sensors. As a direct consequence, the measurement of low-intensity skyglows at stratospheric altitudes could be affected by high-intensity punctual sources acting as lateral disturbances. A dedicated test campaign was therefore conceived and realized to investigate SQM unit response to light sources in the field of view and identify the true angular response curve; the setup consisted in a controlled rotatory stage moving the unit in front of a fixed diffusive light source. Different test conditions were used to validate the experimental procedure, demonstrating the repeatability of the measurements. This paper presents the experimental campaign and the resulting SQM angular response curve; results indicate for both SQMs a larger than expected field of view and the presence of a double peak in the angular response, which is likely related to a non-perfect alignment of SQMs collimation optics. Furthermore, the wider resulting curves suggest that the contribution of lateral sources is more prominent with respect to the response predicted by the manufacturer. For this reason, the utilization of baffles to restrict SQMs field of view is analyzed to minimize the disturbance of lateral light sources and two different geometries are presented.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。