Effect of relative humidity on dynamic aerosols of adenovirus 12

相对湿度对腺病毒12动态气溶胶的影响

阅读:2

Abstract

Dynamic aerosols of adenovirus 12 were generated in the same Henderson apparatus under conditions of high, medium, and low relative humidity. High relative humidities resulted in more recovery of adenovirus 12 from aerosols and lungs of newborn Syrian hamsters. At 89, 51, and 32% relative humidity, the total infectious virus recovered from a 20-min aerosol was 10(6.7), 10(6.0), and 10(4.3) TCD(50), respectively. Hamsters exposed to these 20-min aerosols retained measured lung doses of 10(3.0), 10(2.4), and 10(1.0) TCD(50), respectively. The measured retained lung doses were compared to calculated inhaled lung doses based on both total virus aerosolized and total virus recovery from the aerosols.