Microbiological evaluation of wet and dry floor sanitization systems in hospital patient rooms

医院病房干湿地面消毒系统的微生物学评估

阅读:2

Abstract

A new system for sanitizing floors in hospital patient rooms has been developed. The method consists of dry dusting with a cotton-blend, chemically treated (10% by dry mop weight) dust mop. This method was compared with a conventional cleaning protocol consisting of an initial predusting with the same nongermicidal chemical (3% by dry mop weight) followed by wet mopping with a fresh solution of a quaternary ammonium disinfectant-detergent. Each of six rooms was sampled by using RODAC plates (Becton Dickinson Labware, Oxnard, Calif.) on 10 consecutive days for each of the two methods. The study was initially performed during the summer and then repeated during the winter. Results imply that there is no significant difference between the new dry method (81.9% CFU reduction) and the conventional method (83.1% CFU reduction). Furthermore, the initial dry dusting step in the conventional method accounted for virtually all of the reduction by that method. Thus, wet mopping with a germicidal chemical produced no additional significant reduction of natural microbial populations on environmental surfaces beyond that achieved by dry dusting with dust-suppressant chemicals.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。