Changes in lung volume estimated by electrical impedance tomography during apnea and high-flow nasal oxygenation: A single-center randomized controlled trial

利用电阻抗断层扫描技术估算呼吸暂停和高流量鼻氧疗期间肺容量的变化:一项单中心随机对照试验

阅读:1

Abstract

BACKGROUND: Previous studies concerning humidified, heated high-flow nasal oxygen delivered in spontaneously breathing patients postulated an increase in functional residual capacity as one of its physiological effects. It is unclear wheter this is also true for patients under general anesthesia. METHODOLOGY: The sincle-center noninferiority trial was registered at ClinicalTrials.gov (NCT NCT03478774). This secondary outcome analysis shows estimated differences in lung volume changes using electrical impedance tomography between different flow rates of 100% oxygen in apneic, anesthetized and paralyzed adults prior to intubation. One hundred and twenty five patients were randomized to five groups with different flow rates of 100% oxygen: i) minimal-flow: 0.25 l.min-1 via endotracheal tube; ii) low-flow: 2 l.min-1 + continuous jaw thrust; iii) medium-flow: 10 l.min-1 + continuous jaw thrust; iv) high-flow: 70l.min-1 + continuous jaw thrust; and v) control: 70 l.min-1 + continuous video-laryngoscopy. After standardized anesthesia induction with non-depolarizing neuromuscular blockade, the 15-minute apnea period and oxygen delivery was started according to the randomized flow rate. Continuous electrical impedance tomography measurements were performed during the 15-minute apnea period. Total change in lung impedance (an estimate of changes in lung volume) over the 15-minute apnea period and times to 25%, 50% and 75% of total impedance change were calculated. RESULTS: One hundred and twenty five patients completed the original study. Six patients did not complete the 15-minute apnea period. Due to maloperation, malfunction and artefacts additional 54 measurements had to be excluded, resulting in 65 patients included into this secondary outcome analysis. We found no differences between groups with respect to decrease in lung impedance or curve progression over the observation period. CONCLUSIONS: Different flow rates of humidified 100% oxygen during apnea result in comparable decreases in lung volumes. The demonstrated increase in functional residual capacity during spontaneous breathing with high-flow nasal oxygenation could not be replicated during apnea under general anesthesia with neuromuscular blockade.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。