A retrospective cohort analysis of alignment parameters for spinal tumor patients with instrumentation at the cervicothoracic junction

一项回顾性队列研究分析了颈胸交界处脊柱肿瘤患者内固定术后的脊柱对线参数。

阅读:2

Abstract

BACKGROUND: Previous research on spinal alignment and postoperative outcomes after cervical and upper thoracic fixation has suggested that clinical and patient-reported outcomes are improved when certain anatomical parameters are maintained. These parameters include the cervical sagittal vertical axis (cSVA), C2 and T1 slopes, and cervical lordosis (CL). For patients with primary and metastatic tumors involving the subaxial cervical and/or upper thoracic spine, there is minimal guidance on how to apply these parameters. Surgeons must make critical decisions when designing the optimal construct, considering patient life expectancy, bone quality, oncology goals and deformity. This study aims to evaluate the impact of cervical spine alignment parameters on postoperative hardware failure in spine tumor patients and highlight instances of complications in patients with instrumentation crossing the cervicothoracic junction (CTJ). METHODS: A retrospective review of a single institutional spine tumor database identified seventeen patients who underwent spinal fusion crossing the CTJ from 2015 to 2023. All patients had postoperative neutral standing radiographs with measurable cSVA, C2 and T1 slopes, and/or CL. The primary endpoint was instrumentation failure, defined as hardware pull out or breakage, and secondary endpoints included other complications including wound infection and spinal fluid leak. RESULTS: The number of instrumented levels ranged from 3 to 15 segments with a mean of 7.47. Surgical approaches included anterior (n=3), posterior (n=12), and simultaneous anterior and posterior (n=2). The mean cSVA was 3.39±1.02 cm (range 1.59-4.9 cm). Fourteen patients had measurable C2 slopes with a mean of 25.03±9.16° (range 8.7 - 38.6°). Ten patients had measurable T1 slopes with a mean of 31.5±11.54° (range 18.4-59.6°). Thirteen patients had a measurable CL with a mean of 9.13±9.93° (range 0-37.5°). No cases of instrumentation failure were noted. Four patients experienced other postoperative complications (24%), but rates did not vary with increasing deviation from ideal parameters for cSVA, C2 and T1 slope, or CL. CONCLUSIONS: Although there was wide variability in alignment parameters in this cohort, there were no instances of hardware failure with crossing the CTJ at a mean follow-up of 41 months. The overall complication rate was high at 24%. Despite common concerns about the impact of exaggerated slope and SVA on instrumentation failure these results suggest that cervical and upper thoracic tumor patients may still have a satisfactory result following CTJ fixation, even with unfavorable alignment parameters. Larger prospective studies are needed.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。